Control voltage | AC110V – 220V ±15%, 50/60Hz |
Mains Voltage | AC380V, AC690V, AC1140V ± 15% |
Nominal current | 18A~1000A, 22 rated values in total |
Applicable motor | Squirrel cage AC asynchronous motor |
Start methods | Voltage ramp start, linear torque control start, square torque control start, stepwise frequency control start |
Stop methods | Free stop, soft stop, pump stop, internal brake, external brake |
Logical input | Impedance 1.8 KΩ, Mains voltage +24V |
Start frequency | Frequent or infrequent start available, and it can be set internally |
Protective function | Overvoltage, undervoltage, three-phase voltage imbalance, overcurrent, overload, underload, overheating, phase failure, short circuit, three-phase current imbalance, phase sequence detection, electric leakage, zero sequence detection, motor temperature protection, etc. |
IP | IP00, IP20 |
Cooling type | Natural cooling or forced air cooling |
Installation type | Wall mounted |
Environmental condition | When sea altitude is above 2,000m, soft starter should be derated for use. Ambient temperature: -25 ~ +45°C Relative humidity: less than 95% (20°C±5°C) Free of flammable, explosive and corrosive gas or conductive dust. Indoor installation, good ventilation, vibration less than 0.5G |
No. | Rated current(A) | 380V | 690V | 1140V | |||
Motor Power (kW) | Size | Motor Power (kW) | Size | Motor Power (kW) | Size | ||
1 | 18 | 7.5 | 172×320×167mm | 15 | 172×320×167mm | 22 | 172×320×167mm |
2 | 24 | 11 | 22 | 33 | |||
3 | 30 | 15 | 30 | 45 | |||
4 | 39 | 18.5 | 37 | 55 | |||
5 | 45 | 22 | 45 | 65 | |||
6 | 60 | 30 | 55 | 90 | |||
7 | 76 | 37 | 75 | 110 | |||
8 | 90 | 45 | 90 | 135 | |||
9 | 110 | 55 | 110 | 165 | |||
10 | 150 | 75 | 132 | 285×474×230mm | 225 | ||
11 | 180 | 90 | 285×474×230mm | 160 | 280 | 285×474×230mm | |
12 | 218 | 110 | 200 | 344 | |||
13 | 260 | 132 | 250 | 400 | |||
14 | 320 | 160 | 300 | 505 | 320×512×230mm | ||
15 | 370 | 185 | 350 | 584 | |||
16 | 440 | 220 | 320×512×230mm | 400 | 320×512×230mm | 695 | |
17 | 500 | 250 | 456 | 789 | |||
18 | 560 | 280 | 500 | 884 | 400×647×230mm | ||
19 | 630 | 315 | 560 | 400×647×230mm | 995 | ||
20 | 780 | 400 | 400×647×230mm | 700 | |||
21 | 920 | 470 | |||||
22 | 1000 | 530 |
Applicable motor power (kW) | Model No. | Rated current (A) | Model of bypass contactor | Size of primary wires (copper wire) |
7.5 | CT – 0018/3 | 18 | CJX4-25 | 4 mm2 |
11 | CT – 0024/3 | 24 | CJX4-32 | 6 mm2 |
15 | CT – 0030/3 | 30 | CJX4-32 | 10 mm2 |
18.5 | CT – 0039/3 | 39 | CJX4-40 | 10 mm2 |
22 | CT – 0045/3 | 45 | CJX4-50 | 16 mm2 |
30 | CT – 0060/3 | 60 | CJX4-63 | 25 mm2 |
37 | CT – 0076/3 | 76 | CJX4-80 | 35 mm2 |
45 | CT – 0090/3 | 90 | CJX4-95 | 35 mm2 |
55 | CT – 0110/3 | 110 | CJX4-115F | 35 mm2 |
75 | CT – 0150/3 | 150 | CJX4-150F | 50 mm2 |
90 | CT – 0180/3 | 180 | CJX4-185F | 30×3 copper bar |
110 | CT – 0218/3 | 218 | CJX4-225F | 30×3 copper bar |
132 | CT – 0260/3 | 260 | CJX4-265F | 30×4 copper bar |
160 | CT – 0320/3 | 320 | CJX4-330F | 30×4 copper bar |
185 | CT – 0370/3 | 370 | CJX4-400F | 40×4 copper bar |
220 | CT – 0440/3 | 440 | CJX4-500F | 40×4 copper bar |
250 | CT – 0500/3 | 500 | CJX4-500F | 40×4 copper bar |
280 | CT – 0560/3 | 560 | CJX4-630F | 40×4 copper bar |
315 | CT – 0630/3 | 630 | CJX4-630F | 40×5 copper bar |
400 | CT – 0780/3 | 780 | JWCJ 20-800 | 50×5 copper bar |
470 | CT – 0920/3 | 920 | JWCJ 20-1000 | 50×6 copper bar |
530 | CT – 1000/3 | 1000 | JWCJ 20-1000 | 50×6 copper bar |
Load type | Initial voltage (%) | Start ramp time (s) | Stop ramp time (s) | Current limit ILIM |
Ship propeller | 30 | 10 | 0 | 2.5 |
Centrifugal fan | 50 | 20 | 0 | 3.5 |
Centrifugal pump | 30 | 6 | 6 | 3 |
Piston compressor | 40 | 15 | 0 | 3 |
Lifting machinery | 30 | 15 | 6 | 3.5 |
Mixer | 40 | 15 | 0 | 3.5 |
Crusher | 50 | 15 | 6 | 3.5 |
Screw compressor | 40 | 15 | 0 | 3.5 |
Spiral conveyor belt | 40 | 10 | 6 | 3.5 |
Idling motor | 25 | 10 | 0 | 2.5 |
Belt conveyor | 50 | 15 | 10 | 3.5 |
Heat pump | 30 | 15 | 6 | 3 |
Elevator | 30 | 10 | 0 | 3 |